The Thermal Data

Moving on from the restriction test bench the EK XTX360 radiator was loaded into the thermal test chamber for a series of 9 tests – consisting of 3 flow rates, each having 3 different fan rpm rates tested. I felt the thermal test data was most important and which you as the reader would be most interested in.

Below is the final data results gathered from at least 2 data logging runs at each flow rate and fan rpm combination.  The most stable 15 minute period from each logging run was used and then averaged with the other runs to obtain the data for the table below. A total of 16 temperature sensors were used in the thermal test chamber (8 air in, 2 air out, 3 water in, 3 water out) each take a reading every second and logged via a CrystalFontz unit. The data in the table below is the result of the logging runs which has then been used to create all the plots and tables there-after.

The performance metric of critical importance is the delta between the warm coolant temperature in and the cold ambient air temperature in to the radiator. Given that the system is well insulated and in equilibrium and we know the heat input to the system then we can also calculate a very important number – that is the amount of power required to raise the coolant temperature 1C (or 10C which is more useful reference point).

XTX - Thermal Data Table

Like the vast majority of the other radiators tested, the XTX360 cares little about flow rate for thermal performance, particularly above 1.0GPM. Here are some plots to show the variance:

XTX - Delta Bars

 

So the performance is not greatly affected by varying flow rate. However Delta T is not always helpful when thinking about how many radiators you would need to cool your system. Instead it’s more useful to know the delta/W, or more usefully, the inverse metric of W/delta C. The metric plotted below tells us how many watts are dissipated by the radiator when the coolant rises 10C above ambient temperatures. (10 Delta T):

XTX - W10DT Bars

As expected increasing airflow through the radiator is the primary determinant in changing the radiators performance. This data can now be plotted as a pretty curve so that an end user can interpolate their own fan speed. Note again that the extrapolation of the curve is much more sensitive to error than in between the tested range.  Let’s exclude the push data for now and come back to it:

XTX - W10DT Curves

This makes it easier to see that at higher fan speeds that a low flow starts to impact the cooling performance. This makes sense if you take it to the extreme and think about a very low flow rate where the coolant is already cooled 99% of the way to ambient with 10% of its journey through the radiator. In this example the radiator is not being efficiently used. 90% of the radiator surface area would then be wasted and you could have used a smaller radiator.  Both coolant flow and air flow can limit thermal performance, however in typical systems flow is a much weaker effect than airflow due to typical choices of fans and pumps.

If we now come back to the push data it’s good to compare only the push to push/pull data in an “apples to apples” fashion by only looking at the 1GPM data:
XTX - P Vs PP
Push gives almost exactly 86% of the performance of Push/Pull across the range tested on this radiator.  If you do combine all the plots you’ll also see that at high enough air flow that 1.0GPM Push may overtake 0.5GPM Push/Pull as the flow rate starts to limit performance.

Having said all of this about flow effects they are in reality small.  So in this next plot all three flow rate results were averaged together to produce one curve.  Averaging reduces test error of course so this helps further to be sure of our data and is more useful therefore for comparing to other radiators.

Here one of the top performing and worst performing rads have been plotted also to see how the XTX compares against them. As you can see the XTX performs very well in the midrange and only falls off at very high RPMs.

XTX - Avg'd PP Vs

Now let’s analyze all that data…